H*38DF ST Indoor Gas Fireplace
Page 10
XG0207 - 150204.1
Installation
Section 3: Venting
Figure 9. Flue cover and collar removal, Top Vented replace.
Figure 9a. Flue cover and collar installation, Side Vented replace.
Section 3-1: CONVERTING TO SIDE VENT
Use the following instructions to convert a H*38DF*-ST for Rear Vent use:
1. Remove the Side ue cover and gasket (5" and 8") on the ue
outlet, as shown in Figure 9.
2. Next, Remove the Top ue collar's (5" and 8") on the ue outlet,
as shown in Figure 9.
3. Install the (removed) Side ue cover and gasket material, to the
Top vent outlet. Fasten the cover with included hardware, as
illustrated Figure 9a.
Montigo supplies a variety of direct venting and termination options.
The direct vent termination location MUST be selected such that
it is the highest point in the venting assembly. It should also be
selected such that it provides the shortest vent run possible. Should
it be impossible to ensure that the termination is the highest point or
should it be impossible to meet the venting guidelines laid out below
please contact your Montigo dealer to discuss power venting options.
NOTES FOR PLANNING VENTING:
Venting originates from the unit through the top or through
the side
Venting can terminate through the roof or through an
exterior wall.
Refer to Appendix A - Termination Locations to ensure the
planned termination location is acceptable.
Once the termination location has been established, refer
to the appropriate section below for installation details
All replaces shipped from the factory are Top vent.
Silicone application is NOT required when joining Montigo
vent pipes and components.