Page 6
L-Series DF-ST See-thru Gas Fireplace
Part No. XG0812
Installation
Top Vent Venting Runs
L38DF-ST
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 108" and the horizontal run to
the wall flange of the vent termination is 180", this would be an acceptable
installation.
Example B: (Acceptable Installation)
If the vertical dimension from the hearth is 48" and the horizontal run to
the wall flange of the vent termination is 72", this would be an acceptable
installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 60" and the
horizontal run to the wall flange of the vent termination is 144", this would
NOT be an acceptable installation.
Figure 7a. L38DF -ST Top Vent Venting Graph
NOTES:
All dimension lengths for vertical or horizontal runs are
measured from centre of the vent pipe.
Venting runs must fall within the limits set by the venting
graph (see Figure 9a).
L38DF-ST
Figure 8. Retracted Installation using a combination of solid and flex
venting. Use the vent graph to determine your allowable
run, then select appropriate components.
Figure 9. Horizontal flex installation with MIN vertical rise.
B. Vertical (Through-The-Roof) Installations
5/8" with option for 4/7" (on applicable models)
Vertical rise >12' can be reduced (on applicable models).
Vertical Terminations must be installed:
• minimum 2' (two feet) above the highest point where
vent passes through the roof.
• minimum 6' (six feet) from a mechanical air inlet
• minimum 18" (1 1/2 feet) from a parapet wall.
Maximum vent height is:
32 feet above replace.
32 feet above replace
•
•
L38DF-ST
L42DF-ST
L42DF-ST
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 108" and the horizontal run to
the wall flange of the vent termination is 180", this would be an acceptable
installation.
Example B: (Acceptable Installation)
If the vertical dimension from the hearth is 48" and the horizontal run to
the wall flange of the vent termination is 72", this would be an acceptable
installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 60" and the
horizontal run to the wall flange of the vent termination is 144", this would
NOT be an acceptable installation.
L42DF-ST
Figure 7b. L42DF -ST Top Vent Venting Graph
RHS8
RHS8
42 1/2
A
C
B
39 1/2
B
A
C