Page 8
L-Series DF-ST See-thru Gas Fireplace
Part No. XG0812
Side Vent Venting Requirements
L38DF-ST
If your installation requires more than 12" of horizontal venting, some
vertical lift is required. Use the vent graph below to determine an
acceptable vent run. Unacceptable venting can affect the replace's
performance.
the maximum horizontal vent run is 16 feet
The Venting Graph
Measure the vertical height from the replace hearth to the centre of
the termination and the horizontal run from the from the replace ue
collar to the wall ange of the termination. Plot on the Venting Graph
(Fig. 6) with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 82", and the hori-
zontal run to the wall ange of the vent termination is 156", this
would be an acceptable installation.
Example B: (Acceptable Installation)
If the vertical dimension from the hearth is 72" and the horizontal
run to the wall flange of the vent termination is 36", this would be
an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 48" and
the horizontal run to the wall flange of the vent termination is
108", this would NOT be an acceptable installation.
Short Congurations:
For installations straight through the wall, use an PTO-3/-3F termina-
tion and PXT-5 or PXT-10 to achieve the desired length. The maxi-
mum horizontal vent run with no vertical lift is 12". See Figure 7.
Figure 13a. L38DF -ST Side Vent Venting Graph
L38DF-ST
L42DF-ST
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 82", and the hori-
zontal run to the wall ange of the vent termination is 156", this
would be an acceptable installation.
Example B: (Acceptable Installation)
If the vertical dimension from the hearth is 72" and the horizontal
run to the wall flange of the vent termination is 36", this would be
an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 48" and
the horizontal run to the wall flange of the vent termination is
108", this would NOT be an acceptable installation.
Figure 13a. L42DF -ST Side Vent Venting Graph
L42DF-ST
NOTES: All dimension lengths for vertical or horizontal runs are
measured from centre of the vent pipe.
Venting runs must fall within the limits set by the venting
graph (see Figure 9a).
Horizontal Vent Installation
Vent systems that terminate through a wall may comprise up to
seven different components:
A - Termination PTO-3
PTO-3F
B - Stucco Kits MSR (stucco frame)
MOSR (stucco can)
D - Flex sections PFL-1 (12" section)
PFL-2 (24" section)
PFL-3 (36" section)
PFL-4 (48" section)
E - Rigid sections PEXT-1 (12" section)
PEXT-2 (24" section)
PEXT-3 (36" section)
PEXT-4 (48" section)
F - Extensions PXT- 5 (5" section)
PXT-10 (10" section)
G - 90° elbow PEL-90F/F
PEL-90M/M
H - Heat Shield RHS101 ( for 5"/8" venting)
I - Heat Shield RHS 8 (for Top Venting)
Installation
26 1/2
A
C
B
27 1/2
A
C
B